Preloader

Phone Number :

+91 90149 04444

Email :

info@chromega.in Sales@chromega.in

Address:

Flat No. 801, Madhuban Building, Nehru Place Road, New Delhi

GC (FID, TCD, ECD)

The new-generation CIPL2000 gas chromatograph is benchmarked against international leading brands, and the instrument adopts advanced electronic flow control, microfluidic plate control, high-precision independent temperature control, and other technologies to meet the user's requirements for strong analytical capabilities and reliable stability.

The new-generation CIPL2000 has intelligent functions such as self-diagnosis, self-leak detection, self-saving of carrier gas, automatic reminders, etc., which help you easily grasp the instrument status and solve problems quickly.

Get A Quote Now
In stock Categories : GC (FID, TCD, ECD)

GC (FID, TCD, ECD)

The new-generation CIPL2000 gas chromatograph is benchmarked against international leading brands, and the instrument adopts advanced electronic flow control, microfluidic plate control, high-precision independent temperature control, and other technologies to meet the user's requirements for strong analytical capabilities and reliable stability.

The new-generation CIPL2000 has intelligent functions such as self-diagnosis, self-leak detection, self-saving of carrier gas, automatic reminders, etc., which help you easily grasp the instrument status and solve problems quickly. It can be matched with various pretreatment equipment such as solid phase microextraction, headspace, liquid sampler, etc. to meet your needs for more application expansion.

Features

• Stability, efficiency, and flexibility empower future gas chromatography laboratories
• High-precision electronic gas circuit control ensures accurate and consistent analysis results
• Heart-cutting technology provides more options for separation
• Ultra-deactivated surface treatment technology eliminates matrix effect and invalid peak shape
• Smart interactive experience is combined with classic style

Application

  • Application in energy and chemical industries: The gas chromatograph needs to be closely integrated with the production process in the energy and chemical industries.
  • Application in public security and judicial industries: The alcohol content in blood is determined by headspace dual-channel gas chromatography.
  • Industry Application: Heart-cutting technology to cut the first 5 C2-C3 components (ethane, ethylene, acetylene, propane, and propylene) to the polar column for separation, with the remaining 111 compounds detected on the non-polar column.
  • Food Application: Multi-residue analysis solutions for pesticides in vegetables and fruits.

Specification Table

Category

Item

Specification

1. System Performance

Peak area repeatability

≤0.5% RSD

 

Retention time repeatability

≤0.008% RSD

 

Simultaneous installation support

2 inlets and 4 detectors

 

Electronic Flow Control modules

≥6 modules (24-way gas path control)

 

Heating zones

≥8 independent heating zones

2. Environmental Conditions

Ambient operating temperature range

5 C−35 C or wider

 

Ambient operating humidity range

5%−95% RH or wider

 

Power supply requirements

220 V±10%,50 Hz±10%

3. Column Oven

Temperature control range

Room temperature +4 C−450 C or wider

 

Temperature control accuracy

≤0.01 C

 

Program level

≥32 levels/33 platforms (capable of programmed heating and cooling)

 

Maximum heating rate

≥120 C/min

 

Ambient change compensation

Ambient temp change by 1 C, avg. oven temp changes by ≤0.01 C

4. Electronic Pressure Controller (EPC)

Pressure control accuracy

≤±0.001 psi

 

Pressure control range

0−100 psi or wider

 

Flow rate monitoring range

0−600 mL/min (Nitrogen); 0−1250 mL/min (Hydrogen/Helium)

5. Split/Splitless Inlet

Maximum operating temperature

≥450 C

 

Temperature setting accuracy

≤0.1 C

 

Maximum septum purge flow rate

≥100 mL/min

 

Maximum split ratio

≥1:12500

 

Injection modes

Split, splitless, pulse split, pulse splitless, etc.

 

Applicable columns

Capillary columns (0.1 mm−0.53 mm inner diameter)

6. Detectors

Flame Ionization Detector (FID)

Maximum operating temperature

≥450 C

 

Detection limit

<1.2×10−12 F/s

 

Linear range

≥107 (uses logarithmic amplifier)

 

Signal acquisition frequency

≥200 Hz

Flame Photometric Detector (FPD)

Maximum operating temperature

≥350 C

 

Detection limit

<9×10−14 g/s (P);<5×10−12 g/s (S)

 

Linear range

104(P);103(S)

Electron Capture Detector (ECD)

Maximum operating temperature

≥400 C

 

Detection limit

<3.8×10−14 g/mL

 

Radioactive source

β-rays of 63Ni≤10 mCi

 

Linear range

≥104

Thermal Conductivity Detector (TCD)

Maximum operating temperature

≥300 C

 

Detection limit

<8.7×10−9 g/mL

 

Linear range

≥104

Discharge Helium Ionization Detector (PDHID)

Maximum operating temperature

400 C

 

Discharge mode

pulse discharge

 

Detection limit

1.89×10−13 g/s (propane)

 

Baseline noise

no more than 0.6 pA

 

Baseline drift

no more than 4.5 pA

7. Liquid Autosampler

Syringe specifications

1,5,10,25,50,100,250,500 μL

 

Sample bottle positions

≥9, expandable to 150 sample trays

 

Injections per bottle

1 to 99 times

 

Injection volume

0.1−250 μL

 

Method selection

≥20

 

Maximum needle cleaning times

≥99 times

 

Maximum pumping times

≥99 times

 

Maximum pump-sample interval

≥5000 ms

8. Computer System Requirements

Processor

i5 processor

 

Operating system

Windows 10 64-bit

 

Ports

Two USB ports and one LAN port

 

Memory type/capacity

DDR4 2666, 8 GB

 

Hard disk capacity

1 T mechanical hard disk

 

Optical drive

DVD-rw optical drive, 16x speed DVD burning optical drive or above

 

 